MODELO : NV-RJ16/26/36/46

SINTOMA : Flutuação de Audio
CAUSAS : Troca a mola do rolo pressor verificar Inf. Téc. a respeito

===============================================================

SINTOMA : Sem zoom / Sem foco
CAUSAS : Trocar o motor foco (provavelmente com solda fria ou
enrolamento do motor de foco quebrado.

===============================================================

SINTOMA : Não gira capstan / Não carrega
CAUSAS : Trocar TA8488F

===============================================================

SINTOMA : On Screen sem sincronismo
CAUSAS : Mau contato no cabo ou conector do Viewfinder

===============================================================

SINTOMA : Reproduz mas não grava audio
CAUSAS : Verificar o capacitor C4023 conectado a base do Q4008 oscilador
de Bias